抄録
BACKGROUND/AIMS: We examined the utility of partial splenic embolization (PSE) using a Guglielmi Detachable Coil (GDC) comparing its safety and therapeutic efficacy with those of conventional metallic coils (IDC).
METHODOLOGY: The GDC group comprised 8 patients who were subjected to embolization using a GDC in combination with an IDC, and the IDC group comprised 13 patients. Treatment factors were evaluated by the total number of coils used. We assessed the mean C-reactive protein (CRP) and the increased rate of platelet counts, 2 weeks after treatment.
RESULTS: The rate of increase in platelet counts at 2 weeks after PSE was 2.47 in the GDC group and 3.18 in the IDC group (p = 0.076). The mean CRP levels were 3.0 in the GDC group and 5.9 in the IDC group (p = 0.14). The mean number of coils were 5.3 in the GDC group and 15.3 in the IDC group and this difference was statistically significant (p = 0.0008).
CONCLUSION: A GDC is excellent in terms of stability and allows the operator to conduct embolization of hypersplenism in an accurate and reliable manner. In summary, use of a GDC for hypersplenism reduced the total number of coils required for successful treatment.
本文言語 | 英語 |
---|---|
ページ(範囲) | 683-687 |
ページ数 | 5 |
ジャーナル | Hepato-Gastroenterology |
巻 | 62 |
号 | 139 |
出版ステータス | 出版済み - 1 5月 2015 |