T1 - Reproducibility between three-dimensional turbo spin-echo and two-dimensional dual inversion recovery turbo spin-echo for coronary vessel wall imaging in Kawasaki disease
AU - Matsumoto, Koji
AU - Yokota, Hajime
AU - Yoda, Takafumi
AU - Ebata, Ryota
AU - Mukai, Hiroki
AU - Masuda, Yoshitada
AU - Uno, Takashi
N1 - Publisher Copyright:
© 2022, The Author(s).
PY - 2022/12
Y1 - 2022/12
N2 - Magnetic resonance vessel wall imaging is desirable for evaluating Kawasaki disease (KD)-associated coronary arterial lesions. To evaluate the reproducibility of three-dimensional turbo spin-echo (3D-TSE) and two-dimensional dual inversion-recovery turbo spin-echo (2D-DIR-TSE) for coronary vessel wall imaging in KD. Ten patients were prospectively enrolled. Coronary vessel wall imaging with axial-slice orientation 3D-TSE and 2D-DIR-TSE were acquired for cross-sectional images in aneurysmal and normal regions. Lumen area (LA), wall area (WA), and normalized wall index (NWI) of cross-sectional images were measured in both regions. Reproducibility between 3D-TSE and 2D-DIR-TSE was evaluated via intraclass correlation coefficients (ICCs) and Bland–Altman plots. 48 points (aneurysmal, 27; normal, 21) were evaluated. There were high ICCs between 3D-TSE and 2D-DIR-TSE in LA (0.95) and WA (0.95). In aneurysmal regions, 95% limits of agreement were LA, WA, and NWI of − 29.9 to 30.4 mm2, − 18.8 to 15.0 mm2, and − 0.22 to 0.20, respectively. In normal regions, the 95% limits of agreement were LA, WA, and NWI of − 4.44 to 4.38 mm2, − 3.51 to 4.30 mm2, and − 0.14 to 0.16, respectively. No fixed and proportional biases between 3D-TSE and 2D-DIR-TSE images in aneurysmal and normal regions were noted. 3D-TSE was reproducible with conventional 2D-DIR-TSE for coronary vessel wall assessment on KD.
AB - Magnetic resonance vessel wall imaging is desirable for evaluating Kawasaki disease (KD)-associated coronary arterial lesions. To evaluate the reproducibility of three-dimensional turbo spin-echo (3D-TSE) and two-dimensional dual inversion-recovery turbo spin-echo (2D-DIR-TSE) for coronary vessel wall imaging in KD. Ten patients were prospectively enrolled. Coronary vessel wall imaging with axial-slice orientation 3D-TSE and 2D-DIR-TSE were acquired for cross-sectional images in aneurysmal and normal regions. Lumen area (LA), wall area (WA), and normalized wall index (NWI) of cross-sectional images were measured in both regions. Reproducibility between 3D-TSE and 2D-DIR-TSE was evaluated via intraclass correlation coefficients (ICCs) and Bland–Altman plots. 48 points (aneurysmal, 27; normal, 21) were evaluated. There were high ICCs between 3D-TSE and 2D-DIR-TSE in LA (0.95) and WA (0.95). In aneurysmal regions, 95% limits of agreement were LA, WA, and NWI of − 29.9 to 30.4 mm2, − 18.8 to 15.0 mm2, and − 0.22 to 0.20, respectively. In normal regions, the 95% limits of agreement were LA, WA, and NWI of − 4.44 to 4.38 mm2, − 3.51 to 4.30 mm2, and − 0.14 to 0.16, respectively. No fixed and proportional biases between 3D-TSE and 2D-DIR-TSE images in aneurysmal and normal regions were noted. 3D-TSE was reproducible with conventional 2D-DIR-TSE for coronary vessel wall assessment on KD.
UR - http://www.scopus.com/inward/record.url?scp=85128952612&partnerID=8YFLogxK
U2 - 10.1038/s41598-022-10951-0
DO - 10.1038/s41598-022-10951-0
M3 - Article
C2 - 35478214
AN - SCOPUS:85128952612
SN - 2045-2322
VL - 12
JO - Scientific Reports
JF - Scientific Reports
IS - 1
M1 - 6835
ER -