A Case of Aortopulmonary Fistula with Post-Operative Aortic Pseudoaneurysm Diagnosed by Transesophageal Echocardiography

Katsunori Fukumoto, Yuki Saito, Tetsuro Yumikura, Makoto Taoka, Masashi Tanaka, Yasuo Okumura

研究成果: ジャーナルへの寄稿記事査読

抄録

Tracheobronchial or esophageal fistula after aortic surgery has been reported sporadically in the literature, however, reports of an aortopulmonary fistula associated with a post-operative aortic pseudoaneurysm are rare. We experienced a case of refractory heart failure due to an aortopulmonary fistula associated with a postoperative aortic pseudoaneurysm. A 60-year-old man who had undergone aortic surgery 2 years earlier was hospitalized for congestive heart failure. He was diagnosed with refractory heart failure after 10 days of diuretic therapy failed to improve his condition. He underwent a contrast-enhanced computed tomography (CT) scan and was suspected to have pulmonary artery perforation of an aortic pseudoaneurysm at the anastomotic site of the ascending aortic surgery. Transesophageal echocardiography showed shunt blood flow from the aortic aneurysm into the right pulmonary artery, leading to a definitive diagnosis of aortopulmonary fistula with postoperative aortic pseudoaneurysm. Computed tomography angiography is commonly used to diagnose an aortic fistula; however, diagnosis is often difficult because of the subtle imaging findings. We highlight the usefulness of transesophageal echocardiography in providing a definitive diagnosis and detailed morphologic information on this pathophysiology.

本文言語英語
ページ(範囲)963-966
ページ数4
ジャーナルInternational Heart Journal
65
5
DOI
出版ステータス出版済み - 2024

フィンガープリント

「A Case of Aortopulmonary Fistula with Post-Operative Aortic Pseudoaneurysm Diagnosed by Transesophageal Echocardiography」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル