TY - JOUR
T1 - Long-term progressive degradation of the biological capability of titanium
AU - Minamikawa, Hajime
AU - Att, Wael
AU - Ikeda, Takayuki
AU - Hirota, Makoto
AU - Ogawa, Takahiro
N1 - Publisher Copyright:
© 2016 by the authors.
PY - 2016
Y1 - 2016
N2 - Titanium undergoes time-dependent degradation in biological capability, or "biological aging". It is unknown whether the biological aging of titanium occurs beyond four weeks and whether age-related changes are definitely associated with surface hydrophilicity. We therefore measured multiple biological parameters of bone marrow-derived osteoblasts cultured on newly prepared, one-month-old, three-month-old, and six-month-old acid-etched titanium surfaces, as well as the hydrophilicity of these surfaces. New surfaces were superhydrophilic with a contact angle of ddH2O of 0°, whereas old surfaces were all hydrophobic with the contact angle of around 90°. Cell attachment, cell spread, cell density, and alkaline phosphatase activity were highest on new surfaces and decreased in a time-dependent manner. These decreases persisted and remained significant for most of the biological parameters up to six-months. While the number of attached cells was negatively correlated with hydrophilicity, the other measured parameters were not. The biological capability of titanium continues to degrade up to six months of aging, but these effects are not directly associated with time-dependent reductions in hydrophilicity. A full understanding of the biological aging will help guide regulatory improvements in implant device manufacturing and develop countermeasures against this phenomenon in order to improve clinical outcomes.
AB - Titanium undergoes time-dependent degradation in biological capability, or "biological aging". It is unknown whether the biological aging of titanium occurs beyond four weeks and whether age-related changes are definitely associated with surface hydrophilicity. We therefore measured multiple biological parameters of bone marrow-derived osteoblasts cultured on newly prepared, one-month-old, three-month-old, and six-month-old acid-etched titanium surfaces, as well as the hydrophilicity of these surfaces. New surfaces were superhydrophilic with a contact angle of ddH2O of 0°, whereas old surfaces were all hydrophobic with the contact angle of around 90°. Cell attachment, cell spread, cell density, and alkaline phosphatase activity were highest on new surfaces and decreased in a time-dependent manner. These decreases persisted and remained significant for most of the biological parameters up to six-months. While the number of attached cells was negatively correlated with hydrophilicity, the other measured parameters were not. The biological capability of titanium continues to degrade up to six months of aging, but these effects are not directly associated with time-dependent reductions in hydrophilicity. A full understanding of the biological aging will help guide regulatory improvements in implant device manufacturing and develop countermeasures against this phenomenon in order to improve clinical outcomes.
KW - Biological aging
KW - Bone-implant integration
KW - Dental and orthopedic implants
KW - Hydrophilicity
KW - Osseointegration
UR - http://www.scopus.com/inward/record.url?scp=84960130768&partnerID=8YFLogxK
U2 - 10.3390/ma9020102
DO - 10.3390/ma9020102
M3 - Article
AN - SCOPUS:84960130768
SN - 1996-1944
VL - 9
JO - Materials
JF - Materials
IS - 2
M1 - 102
ER -